- 07RiskExtendedPCD21/30
Myth: Encryption alone makes our device secure.
Reality. Encryption protects data in transit and at rest, but doesn't address authentication, authorization, secure boot, key management, or insecure defaults, where most breaches actually occur.
- 10LeadershipExtendedPCD22/30
Myth: A breach won't happen to us, we're too small.
Reality. Smaller manufacturers are targeted precisely because they have fewer defenses. Ransomware groups now treat MedTech supply chains as soft entry points to hospitals.
- 12EngineeringExtendedPCD22/30
Myth: Moving to the cloud means our cloud provider handles security.
Reality. Cloud is a shared-responsibility model. AWS/Azure/GCP secure the infrastructure; you still own identity, data, configuration, network policy, and the SaMD application itself.
- 20RiskExtendedPCD20/30
Myth: Cyber insurance will cover us if something goes wrong.
Reality. Cyber policies increasingly exclude losses from missing controls (no MFA, no patching program, no SBOM). Premiums have spiked 50–100% and carriers are denying claims for foreseeable failures.
- 28EngineeringExtendedPCD19/30
Myth: Running our SaMD on Kubernetes makes it secure.
Reality. Kubernetes is powerful, not secure by default. Default service accounts, permissive network policies, exposed dashboards, and unsigned images are the norm. SaMD on K8s still owns the cluster's security posture under the shared responsibility model.
- 30ProcessCanonPCD26/30
Myth: Our incident response plan is the IT team's runbook.
Reality. Medical device incidents trigger overlapping obligations: FDA MDR reporting, HHS breach notification (if PHI), CISA coordinated disclosure, customer comms, and clinical risk assessment. A generic IT runbook misses every regulator-specific clock.
- 42ProcessExtendedPCD23/30
Myth: Decommissioning a device is just paperwork.
Reality. End-of-life devices contain PHI on internal storage, embedded credentials, and active certificates. Without media sanitization (NIST SP 800-88), credential rotation, and certificate revocation, decommissioned units resurface on eBay with full hospital network access intact.
- 44EngineeringExtendedPCD24/30
Myth: Putting medical devices on a separate VLAN is enough segmentation.
Reality. A flat medical VLAN with bidirectional EHR, PACS, and clinical-workflow access is a soft target. Real segmentation requires microsegmentation by device type and risk, east-west inspection, and explicit allow-lists for clinical traffic, not just a separate broadcast domain.
- 45ProcessExtendedPCD24/30
Myth: If a clinician signs up for a SaaS tool with their work email, that's not our problem.
Reality. Clinical SaaS, AI scribes, and patient-engagement tools introduced via shadow IT fall under HIPAA business associate, FDA SaMD, and procurement security review, even when no PO was issued. The hospital, not the vendor, owns the breach.
- 47EngineeringExtendedPCD22/30
Myth: Zero trust is for enterprise IT, not embedded medical devices.
Reality. Zero trust principles, verify explicitly, least privilege, assume breach, apply directly to device fleets: per-device identity, mTLS for service traffic, continuous attestation, and revocable short-lived credentials. NIST SP 800-207 and the DHS CISA Zero Trust Maturity Model both extend to OT and IoMT.