Archive

    Cryptography misconceptions

    Cryptographic posture, key management, and crypto-agility for medical devices.

    9 of 50 misconceptions match.

    Filter by

    Device type

    Risk area

    Regulation

    Protocol

    1. 05Engineering
      Extended
      P
      C
      D
      22/30

      Myth: Penetration testing is the same as a security assessment.

      Reality. A pentest finds exploitable bugs in a finished product. A security assessment evaluates threat models, architecture, SDLC, cryptographic choices, and supply chain, long before code freezes.

    2. 07Risk
      Extended
      P
      C
      D
      21/30

      Myth: Encryption alone makes our device secure.

      Reality. Encryption protects data in transit and at rest, but doesn't address authentication, authorization, secure boot, key management, or insecure defaults, where most breaches actually occur.

    3. 17Engineering

      Myth: Devices in the field don't need to support secure updates.

      Reality. Section 524B explicitly requires the ability to deploy postmarket updates and patches in a reasonable time. That means signed firmware, integrity verification, rollback protection, and a deployment plan.

    4. 18Compliance
      Extended
      P
      C
      D
      21/30

      Myth: Security testing belongs in V&V at the end of the project.

      Reality. Security activities run in parallel with the entire SDLC: threat modeling at design, SAST in CI, DAST in integration, fuzzing on protocols, pentest before release. V&V verifies, it doesn't discover.

    5. 25Engineering
      Extended
      P
      C
      D
      21/30

      Myth: Application-layer security is enough, hardware is fine.

      Reality. Without secure boot, hardware root of trust, debug-port lockdown, and side-channel protections, an attacker with brief physical access can dump firmware, extract keys, and persist below your OS. Implantables and bedside devices both qualify.

    6. 26Engineering
      Extended
      P
      C
      D
      25/30

      Myth: Our crypto is fine, we don't need to think about it again.

      Reality. RSA-2048 and ECC will fall to a cryptographically relevant quantum computer. Devices shipping today with 10-15 year service lives need crypto agility, the ability to swap algorithms in the field, and a path to NIST PQC standards (ML-KEM, ML-DSA).

    7. 32Compliance
      Extended
      P
      C
      D
      22/30

      Myth: A Predetermined Change Control Plan lets us update our AI model whenever we want.

      Reality. PCCPs authorize specific, pre-described modifications under defined verification and validation. Anything outside the boundary is a new submission. Cybersecurity controls (data integrity, model signing, monitoring) are part of what FDA expects to see described in the PCCP.

    8. 49Engineering
      Extended
      P
      C
      D
      19/30

      Myth: USB-C and Thunderbolt are fine, we lock the OS.

      Reality. Thunderbolt and USB4 expose PCIe via DMA. Without IOMMU/Kernel DMA Protection enforced and unsigned-peripheral blocking, an attacker with seconds of physical access can read memory and bypass disk encryption, regardless of OS login state. Bedside and cart-mounted devices are the obvious targets.

    9. 50Engineering
      Extended
      P
      C
      D
      22/30

      Myth: Secure boot is our hardware root of trust.

      Reality. Secure boot verifies the boot chain, but a real hardware root of trust adds device identity, remote attestation, sealed key storage, and rollback protection in immutable hardware (TPM, SE, or RoT IP). Without attestation, hospitals and regulators can't prove a fielded device is running the firmware you shipped.

    Looking for the full library?

    The Library offers full-text search and tag filters across all 50 misconceptions.

    Open Library