Archive

    EU MDR misconceptions

    EU MDR and MDCG cybersecurity guidance for European market access.

    7 of 50 misconceptions match.

    Filter by

    Device type

    Risk area

    Regulation

    Protocol

    1. 08Compliance

      Myth: We passed last year, we're still compliant.

      Reality. FDA guidance (2023 → 2025 → Feb 2026), EU MDR, and IEC 81001-5-1 evolved significantly. Postmarket requires continuous monitoring, coordinated vulnerability disclosure, and timely patching.

    2. 23Compliance

      Myth: If we're cleared by the FDA, the EU will accept the same package.

      Reality. EU MDR Annex I §17.2 and the Cyber Resilience Act impose distinct cybersecurity requirements. Notified Bodies want IEC 81001-5-1 evidence, MDCG 2019-16 alignment, and CRA-style essential requirements, not an FDA cover letter.

    3. 29Process

      Myth: If we find a serious vulnerability, we'll just issue a recall.

      Reality. FDA expects you to patch first when feasible. A recall for a software vulnerability is a Class I/II event with MDR reporting, customer notification, and reputational fallout. Devices designed for secure OTA updates avoid most recalls.

    4. 30Process

      Myth: Our incident response plan is the IT team's runbook.

      Reality. Medical device incidents trigger overlapping obligations: FDA MDR reporting, HHS breach notification (if PHI), CISA coordinated disclosure, customer comms, and clinical risk assessment. A generic IT runbook misses every regulator-specific clock.

    5. 34Process
      Extended
      P
      C
      D
      23/30

      Myth: Once our AI model is validated, performance monitoring is a nice-to-have.

      Reality. Model drift, data drift, and shifting clinical populations degrade performance silently. GMLP principle 9 and FDA's lifecycle approach require ongoing performance monitoring with thresholds and a defined response, security incidents include integrity, not just confidentiality.

    6. 36Compliance
      Extended
      P
      C
      D
      23/30

      Myth: The EU Cyber Resilience Act doesn't apply to us, we're regulated under MDR.

      Reality. Most medical devices are exempted from CRA's substantive obligations because MDR/IVDR cover them, but only if MDR cybersecurity expectations are actually met. Accessories, standalone software, and components may still fall under CRA. The 36-month transition (full applicability Dec 2027) is now.

    7. 39Compliance
      Extended
      P
      C
      D
      19/30

      Myth: Australia's TGA mirrors FDA, so cybersecurity evidence transfers cleanly.

      Reality. TGA's Medical Device Cyber Security Guidance maps to Essential Principles and Australian-specific postmarket obligations. SaMD reclassifications (effective 2021) and 2024 IMDRF-aligned updates demand evidence packaged to TGA's structure, not FDA's.

    Looking for the full library?

    The Library offers full-text search and tag filters across all 50 misconceptions.

    Open Library